logo
Found 90 products for "

camera head parts

"
Kalite BF-260 Bronhoscope için Olympus CCD Tıbbi prosedürler için fabrika

BF-260 Bronhoscope için Olympus CCD Tıbbi prosedürler için

Olympus CCD for BF-260 Bronchoscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260,

Kalite Olympus CCD For GIF-XQ260 CCD Serisi ile Gastroskop fabrika

Olympus CCD For GIF-XQ260 CCD Serisi ile Gastroskop

Olypmus CCD for GIF-XQ260 Gastroscope Spare parte of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF

Kalite Tıbbi Ekipman Parçaları Sonoscape L743 Lineer Prob Onarımı fabrika

Tıbbi Ekipman Parçaları Sonoscape L743 Lineer Prob Onarımı

Sonoscape L743 linear probe for repair ► Brief Description Fault: Probe head broken. Solution: Replace probe head.(including crystal and upper housing). ►Problem & Solutoin Brand Sonoscape Model L743 Fault Probe head broken Solution Replace probe head.(including crystal and upper housing) ► Common issues with L743 Probes No Image or Intermittent Image Poor Image Quality Probe Not Recognized/Detected Physical Damage to the Probe Head or Cable Overheating Probe Gel Leakage If

Kalite Gelişmiş Endoskopi için Olympus CCD For GIF-Q260 Gastroskopu fabrika

Gelişmiş Endoskopi için Olympus CCD For GIF-Q260 Gastroskopu

Olympus CCD For GIF-Q260 Gastroscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260

Kalite GE 4C-RS karın sondası tamir için fabrika

GE 4C-RS karın sondası tamir için

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

Kalite 1898200T M4 Düz Ateşli Mikrodebrider ve Tamir için el parçası fabrika

1898200T M4 Düz Ateşli Mikrodebrider ve Tamir için el parçası

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside

Kalite Insighters IS3-F laryngoskop tamir için fabrika

Insighters IS3-F laryngoskop tamir için

Insighters IS3-F laryngoscope for repair ► Brief Description Fault: 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution: Replace CCD, insert tube, bending section, rubber ►Problem & Solutoin Brand Insighters Model IS3-F Fault 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution Replace CCD, insert tube, bending section, rubber ► Common

Kalite T-R0035 Olympus Stryker Bench Vice için Endoskopi Tamir Uzmanı fabrika

T-R0035 Olympus Stryker Bench Vice için Endoskopi Tamir Uzmanı

Product Description 1. Introduction T-R0035 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Bench Vice Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0035 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Iron Weight: 10KG 3.Functions: Disassembly and assembly 4.Quality and Reliability High-quality iron raw materials CNC machined

Kalite Ultrason Dönüştürücü için özelleştirilebilir Yenilikçi Kablo fabrika

Ultrason Dönüştürücü için özelleştirilebilir Yenilikçi Kablo

Cable for Ultrasound Transducer ► Brief Description An ultrasound transducer cable is a highly engineered, specialized piece of hardware. It is responsible for transmitting delicate, high-frequency electrical signals between the ultrasound machine and the piezoelectric elements in the probe head, all while enduring constant flexing, twisting, and chemical disinfection. ► Features High-Fidelity Signal Transmission Noise Isolation and EMI Shielding Ergonomics and Flexibility