Kalite Tıbbi Cihaz Tamiri GE RIC5-9-D TAMIRLIK için ULTRASOND PROBE fabrika

Tıbbi Cihaz Tamiri GE RIC5-9-D TAMIRLIK için ULTRASOND PROBE

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in ...

Kalite OLYMPUS CF-HQ190L Tıbbi Cihaz Onarım Koperleri Onarım Aracı Koperleri fabrika

OLYMPUS CF-HQ190L Tıbbi Cihaz Onarım Koperleri Onarım Aracı Koperleri

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not ...

Kalite Düzeltmek için GE 4D3C-L 4D Konveks Dönüştürücü fabrika

Düzeltmek için GE 4D3C-L 4D Konveks Dönüştürücü

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...

Kalite GE 4C-RS karın sondası tamir için fabrika

GE 4C-RS karın sondası tamir için

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS ...

Kalite S5-2 Kardiyak onarım probu fabrika

S5-2 Kardiyak onarım probu

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain ...

Kalite Olympus LTF-160 torakoskop onarımı için fabrika

Olympus LTF-160 torakoskop onarımı için

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...

Kalite Düzeltmek için OLYMPUS CF-H180AL Elektronik Kolonoskop fabrika

Düzeltmek için OLYMPUS CF-H180AL Elektronik Kolonoskop

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Kalite SonoScape EG-500 Elektronik Gastroskopik Onarım için fabrika

SonoScape EG-500 Elektronik Gastroskopik Onarım için

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...

Kalite Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube fabrika

Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube

Olympus/ Pentax/ Fuji A/W Tube ► Brief Description The "air/water channel" is a critical part of a flexible endoscope's function. The tube you are referring to is most commonly known as the Air/Water Valve Tube or A/W Tube . It's a small, transparent, and highly flexible tube that connects the air ...