Kalite SonoScape EG-500 Elektronik Gastroskopik Onarım için fabrika

SonoScape EG-500 Elektronik Gastroskopik Onarım için

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...

Kalite Düzeltmek için OLYMPUS TJF-Q180V Elektronik Duodenoskop fabrika

Düzeltmek için OLYMPUS TJF-Q180V Elektronik Duodenoskop

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...

Kalite Olympus LTF-160 torakoskop onarımı için fabrika

Olympus LTF-160 torakoskop onarımı için

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...

Kalite R Wolf 7326071 üreteroskop onarımı için fabrika

R Wolf 7326071 üreteroskop onarımı için

R Wolf 7326071 ureteroscope for repair ► Brief Description Fault: The image has spots,image bundle aging,light bundle broken;Insert tube aging;Biopsy channel worn and leakage;Bending section,wire and helix tube were worn. Solution: Replace the light bundle,image bundle,rubber,biopsy channel,helix ...

Kalite Tamir için Olympus CYF V2 Kistoskopu fabrika

Tamir için Olympus CYF V2 Kistoskopu

Olympus CYF V2 Cystoscope For Repair ► Brief Description Fault: Leakage. Solution: Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber. ►Problem & Solutoin Brand Olympus Model CYF V2 Fault Leakage Solution Replace the insert tube, light bundle, biopsy ...

Kalite Tamir için Olympus A70940A Otoklavlı Artroskop fabrika

Tamir için Olympus A70940A Otoklavlı Artroskop

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Kalite GIF-XQ240 Gastroskop Olympus tarafından tamir için fabrika

GIF-XQ240 Gastroskop Olympus tarafından tamir için

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common ...

Kalite Olympus 290 Tıbbi Ekipman Tamiri Sertifikası Kursu Kolonoskopi ve Bronhoskopi Güney Koreli Müşteri için fabrika

Olympus 290 Tıbbi Ekipman Tamiri Sertifikası Kursu Kolonoskopi ve Bronhoskopi Güney Koreli Müşteri için

The courses we organize and their contents are as follows. COURSE: Olympus 290 Colonoscopy and Bronchoscopy Repair Training Course Brands: OLYMPUS, FUJINON Duration: 5 Days / 4 hours per day (20 hours total) Course Schedule: Courses run on demand. We open the course when you ask for it and arrange ...

Kalite Olympus CF-H190L Kolonoskop için Değişken Sertlik Bobine Montajı fabrika

Olympus CF-H190L Kolonoskop için Değişken Sertlik Bobine Montajı

Variable Stiffness Coil Assembly For Olympus CF-H190L Colonoscope ►Brief Description The Variable Stiffness Wire/Coil is a core mechanical element of Olympus’s proprietary RIT (Responsive Insertion Technology) found in the CF-H190L colonoscope. Unlike gastroscopes, colonoscopes navigate acute loops ...