logo
Found 90 products for "

rigid endoscope repair

"
Kalite Güney Koreli müşteri için esnek endoskop eğitimi. fabrika

Güney Koreli müşteri için esnek endoskop eğitimi.

The courses we organize and their contents are as follows. COURSE: Flexible Endoscope Repair Training Course Brands: OLYMPUS, FUJINON Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope Duration: 5 Days / 4 hours per day (20 hours total) Course Schedule: ...

Kalite Karl Storz 27005BA endoskop tamir için fabrika

Karl Storz 27005BA endoskop tamir için

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Kalite Alman kaliteli Ureterorenoskop 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr Hastane için fabrika

Alman kaliteli Ureterorenoskop 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr Hastane için

German-quality Ureterorenoscope 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr For Hospital ► Brief Description The function of a ureterorenoscope (URS) is primarily to allow a urologist to visualize, diagnose, and treat conditions in the upper urinary tract, which includes the ureter (the tube carrying ...

Kalite Onarım için Olympus TJF-160VR endoskop fabrika

Onarım için Olympus TJF-160VR endoskop

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The ...

Kalite Tamir için Olympus CHF-P20Q endoskopu fabrika

Tamir için Olympus CHF-P20Q endoskopu

Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & ...

Kalite Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd Kablosu için Onarım Aracı fabrika

Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd Kablosu için Onarım Aracı

REPAIR TOOLS FOR OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD CABLE Brand: OLYMPUS Model: OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD Condition: Brand new A repair tool that can be used to repair OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD cable. It can be ...

Kalite Tamir için Olympus CF-H190L Kolonoskop fabrika

Tamir için Olympus CF-H190L Kolonoskop

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

Kalite Tamir için Olympus GIF-Q180 gastroskopu fabrika

Tamir için Olympus GIF-Q180 gastroskopu

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

Kalite GIF-XQ240 Gastroskop Olympus tarafından tamir için fabrika

GIF-XQ240 Gastroskop Olympus tarafından tamir için

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common ...