Found 90 products for "

rigid endoscope repair

"
Kalite Suya Dayanıklı Başlık MH-553 Olympus Esnek Video Endoskopları İçin fabrika

Suya Dayanıklı Başlık MH-553 Olympus Esnek Video Endoskopları İçin

Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes ► Brief Description The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive electrical connectors of a flexible endoscope during the cleaning, disinfection, and sterilization processes. ► Features Water Ingress Protection Leakage Testing Support Reprocessing

Kalite PENTAX Medical EPK-i7000 Video İşlemci Tamir İçin fabrika

PENTAX Medical EPK-i7000 Video İşlemci Tamir İçin

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: Six months. ►Problem & Solution Brand PENTAX Model EPK-i7000 Product Processor Fault It cannot recognize the endoscope and reports an error. Solution Repair the system board. ►

Kalite Eus Endoskoplar için Esnek Endoskop Parçaları Olympus Emme Valfı fabrika

Eus Endoskoplar için Esnek Endoskop Parçaları Olympus Emme Valfı

Detail olympus suction valve maj-1443 for eus endoscopes Olympus SUCTION VALVE MAJ-1443 Brand: Olympus Series: SUCTION VALVE Model:MAJ-1443 Description .Suction Valve, Autoclavable, Non-Sterile, Reusable, For EUS Endoscopes . Helps prevent backflow . Reusable CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound,

Kalite Olympus Esnek Endoskop için MAJ-1444 Hava Su Valvu fabrika

Olympus Esnek Endoskop için MAJ-1444 Hava Su Valvu

Air Water Valve MAJ-1444 ► Brief Description The Olympus MAJ-1444 is an Air/Water Valve primarily used with Olympus Ultrasonic Endoscopes (EUS - Endoscopic Ultrasound). This valve plays a crucial role during endoscopy procedures, enabling the controlled delivery of air and water to the endoscope's distal tip. ► Features Air Insufflation Water Jet/Washing Cleaning the Objective Lens Washing the Examination Area Balloon Inflation (for EUS probes) One-Way Valve Functionality

Kalite Tamir için Olympus A70940A Otoklavlı Artroskop fabrika

Tamir için Olympus A70940A Otoklavlı Artroskop

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

Kalite Olympus A4674A Otoklavlanabilir Histeroskop (Onarım için) fabrika

Olympus A4674A Otoklavlanabilir Histeroskop (Onarım için)

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur

Kalite Karl Storz 27005BA Cystoscope for repair fabrika

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Kalite Tıbbi Cihaz Tamir Çantaları Tamir için Olympus CF-H190L Kolonoskop fabrika

Tıbbi Cihaz Tamir Çantaları Tamir için Olympus CF-H190L Kolonoskop

Olympus CF-H190L Colonoscope for repair,SN:261****. Fault:Light bundle broken,biopsy tube worn,water air tube leakage,bending section deformation,wire helix tube worn. Solution:Replace the bending section,wire,helix tube,air tube and rubber.PS:Warranty for replace parts only. Repair time:7 working days. Repair price:$****. Warranty:90 days. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories,

Kalite Tıbbi Cihaz Tamiri GE RIC5-9-D TAMIRLIK için ULTRASOND PROBE fabrika

Tıbbi Cihaz Tamiri GE RIC5-9-D TAMIRLIK için ULTRASOND PROBE

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.